Metal Clad 705FR LT
Metal Clad 705FR LT
Low Temp Burn and UV Resistant Air & Vapor Barrier
Metal Clad 705FR LT is a self-adhered water resistive air barrier membrane comprised of rubberized asphalt and dual layers of high-strength polyethylene with a surface layer of metallic aluminum film. Due to its metallic surfacing, Metal Clad 705FR LT exhibits excellent weathering and burn resistance when applied to above-grade wall assemblies. The thick layer of tacky rubberized asphalt provides a durable bond over substrates and laps while it seals around common types of penetrating fasteners. This vapor impermeable membrane is available in various roll widths for both membrane and flashing applications and has a removable release liner for ease of installation.
Sizes Available:
6”
x100'
9"
x100'
12”
x100'
18”
x100'
36"
x 75'
40 mils
Thickness
Product Details
FORMERLY Henry Blueskin Metal Clad LT and CCW Fire Resist™ 705FR-A XLT
Henry Metal Clad 705FR LT is a self-adhered membrane comprised of an extra tacky rubberized asphalt adhesive factory-applied to a composite facer of cross-laminated HDPE and aluminum foil. The product is best installed from 15°F to 80°F (-9°C to 27°C). The metallic surfacing affords Metal Clad 705FR LT excellent weathering and burn resistance when applied in above-grade wall assemblies. This air and vapor barrier membrane is available in various roll widths for both membrane and flashing applications and has a removable release liner for ease of installation.
- Factory applied thickness and composition – Assured even coverage
- Fully adhered 35-mils (0.9mm) of adhesive – Bites into rough substrates, seals around penetrating fasteners
- Extra tacky adhesive formula allows easy installation as low as 15°F (-9°C)
- Adhesion and compatibility of facer with many sealants and adhesives – Facilitates system tie-ins
- Compatible with other Henry air barrier system components – Enables longer system UV exposure
Usage:
Designed for use as a self-adhered air, vapor, and water-resistive barrier. It can also be used as a flashing/transition sheet in conjunction with Henry Air-Bloc® and Barritech™ fluid applied membranes.
-
LOW-TEMP APPLICATION
Can be installed in temperatures ranging from 15°F to 80°F (-9°C to 27°C)
-
NFPA 285 COMPLIANT
Meets IBC 1403.5 exception #2 – Fire safety compliant in many wall assemblies
-
LONGER UV EXPOSURE
Can be left exposed for up to 12 months - Allows for greater schedule flexibility
-
FEATURES FOR EASIER INSTALLATION
Stiffer, boardier printed facer and lap lines on 36” width sheets provide easy product identification and aids installation
Technical & Installation
-
Metal Clad 705FR LT Guide Spec
Download
-
Metal Clad 705FR and Metal Clad 705FR LT
Download
-
M705-00.1-Detail-index
Download
-
M705-0A.1-System-components
Download
-
M705-0B.1-Typical-assemblies-exterior-walls
Download
-
M705-1A.1-Air-barrier-installation-sheathing
Download
-
M705-1A.2-Air-barrier-installation-sheathing
Download
-
M705-1B.1-Air-barrier-installation-masonry
Download
-
M705-2B.1-Air-barrier-transition-self-adhered-flashing
Download
-
M705-2B.2-Air-barrier-transition-self-adhered-flashing
Download
-
M705-3A.1-Sheathing-joints
Download
-
M705-3B.1-Masonry-joints
Download
-
M705-3C.1-Pre-cast-concrete-panel-joints
Download
-
M705-4A.1-Control-joints-sheathing-substrates
Download
-
M705-4B.1-Control-joints-masonry-substrates
Download
-
M705-4C.1-Expansion-joints-bellows-flashing-method
Download
-
M705-4C.2-Expansion-joints-bulb-flashing-method
Download
-
M705-5A.1-Non-flanged-window-self-adhered-flashing-before-WRB
Download
-
M705-5A.2-Non-flanged-window-self-adhered-flashing-after-WRB
Download
-
M705-5B.1-Flanged-window-self-adhered-flashing-before-WRB
Download
-
M705-5B.2-Flanged-window-self-adhered-flashing-after-WRB
Download
-
M705-5R.1-Door-jamb-flashing
Download
-
M705-6A.1-Masonry-anchors-sheathing-substrates
Download
-
M705-6A.2-Masonry-anchors-sheathing-substrates
Download
-
M705-6B.1-Masonry-anchors-masonry-substrates
Download
-
M705-6C.1-Furring-and-girts
Download
-
M705-6D.1-Insulation-attachment
Download
-
M705-6E.1-Window-head-flashing-shelf-angle
Download
-
M705-7A.1-Shelf-angle-continuous-at-floor-line
Download
-
M705-7B.1-Shelf-angle-thermal-break
Download
-
M705-7C.1-Knife-plate
Download
-
M705-9A.1-Dissimilar-substrates-CMU-to-steel-column
Download
-
M705-9B.1-Dissimilar-substrates-stud-wall-to-concrete
Download
-
M705-9C.1-Dissimilar-substrates-CMU-to-concrete
Download
-
M705-9D.1-Dissimilar-substrates-CMU-to-stud-wall
Download
-
M705-10A.1-Inside-and-outside-corners-on-sheathing-self-adhered-flashing
Download
-
M705-10C.1-Inside-and-outside-corners-on-CMU-substrates
Download
-
M705-11A.1-Pipe-penetration-liquid-applied-flashing
Download
-
M705-11B.1-Pipe-penetration-self-adhered-flashing
Download
-
M705-12A.1-Air-barrier-tie-in-at-deck
Download
-
M705-12C.1-Balcony -upturn-at-deck-to-wall
Download
-
M705-13A.1-Air-barrier-tie-in-to-roofing-at-parapet
Download
-
M705-13A.2-Air-barrier-tie-in-to-roofing-at-parapet
Download
-
M705-13B.1-Air-barrier-tie-in-to-roofing-at-drip-edge
Download
-
M705-14A.1-Air-barrier-tie-in-to-foundation-slab-below-grade
Download
-
M705-14B.1-Air-barrier-tie-in-to-foundation-slab-on-grade
Download
-
M705-14C.1-Air-barrier-tie-in-to-foundation-no-masonry-ledge
Download
-
Henry® Air Barrier Assemblies Meet ASTM E2357
Download
-
Henry® Living Building Challenge: Red List Status
Download
-
Henry® NFPA 285 Air Barrier Assemblies
Download
-
Henry Air Barriers NFPA 285 Exception 2
Download
-
Henry® Self-Adhered, Rubberized Asphaltic Membranes / Chemical Compatibility
Download
-
Henry Air Barrier and Waterproofing Membranes Earn Living Building Challenge Declare "Red List Free" Status
Download