Blueskin® VP160

Self-Adhered Water Resistive Air Barrier

Blueskin<sup>®</sup> VP160

Blueskin® VP160

Self-Adhered Water Resistive Air Barrier

Henry® Blueskin® VP160 is a self-adhered vapor permeable, water resistive air barrier membrane consisting of an engineered film and a patented, permeable adhesive technology with split-back poly-release film. Blueskin® VP160 is fully adhered to the wall substrates in a weatherboard method without mechanical attachment.

Features

  • Meets highest industry standards for commercial air barriers
  • Sheds water while allowing vapor to pass through allowing walls to drain and substrates to dry
  • Creates a continuous plane of air-tightness helping to improve building thermal performance
  • Fully adheres to substrates eliminating water migration

Packaging:

  • 4” x 100’
  • 6” x 100’
  • 9” x 100’
  • 12” x 100’
  • 48” x 100’

Color:

  • Blue

Complete the system

Literature

  • Installation and Technical Literature

    Blueskin® VP160 Data Sheet Click to download  

    Blueskin® VP160 SDS Sheet Click to download  

    Blueskin® VP160 Installation Manual Click to download  

    Blueskin® VP160 Health Product Declaration Click to download  

    ICC-ES Evaluation Report Click to download  

  • Tech-Talks

    Henry Air Barrier and Waterproofing Membranes Earn Living Building Challenge Declare "Red List Free" Status Click to download

    NFPA 285 Assemblies Click to download

    Fastener penetrations through air barrier membranes Click to download

    Blueskin® VP Cold Weather Application Click to download

    Henry® Air Barrier Assemblies Meet ASTM E2357 Click to download

    Henry® Living Building Challenge Red List Click to download

  • Specifications

    Blueskin® VP160 Guide Spec Click to download  

  • Architectural Details

    BSVP160_3D1-Vertical-Installations_US pdf cad

    BSVP160_3D2-Horizontall-Installations_US pdf cad

    BSVP160-1A1-Wall-Foundation_Slab-Below-Grade_US pdf cad

    BSVP160-1A3-Wall-Foundation_Slab-Below-Grade_CM100-Transition_US pdf cad

    BSVP160-1B1-Wall-Foundation_Slab-on-Grade_US pdf cad

    BSVP160-1B3-Wall-Foundation_Slab-on-Grade_CM100-Transition_US pdf cad

    BSVP160-1C1-Wall-Foundation_No-Brick-Ledge_US pdf cad

    BSVP160-1C2-Wall-Foundation-Transition_No-Brick-Ledge_US pdf cad

    BSVP160-1C3-Wall-Foundation_No-Brick-Ledge_CM100-Transition_US pdf cad

    BSVP160-2A-Pipe-Penetration_Half-Inch-Gap-Max_Sealant_US pdf cad

    BSVP160-2B-Pipe-Penetration_Half-Inch-Gap-Max_Liquid-Flashing_US pdf cad

    BSVP160-2C-Pipe-Penetration_Three-Quarter-Inch-Gap-Max_Self-Adhered-Flashing_US pdf cad

    BSVP160-3A-Inside-and-Outside-Corners_US pdf cad

    BSVP160-4A1-Column-Transition_Self-Adhered-Flashing_US pdf cad

    BSVP160-5A1-Thru-Wall-Flashing_Blueskin-TWF_US pdf cad

    BSVP160-6A1A-Rebate-Window_Section_Method-A_US pdf cad

    BSVP160-6A1B-Rebate-Window_Section_Method-B_US pdf cad

    BSVP160-6A2A-Flanged-Window_Section_Method-A_US pdf cad

    BSVP160-6A2B-Flanged-Window_Section_Method-B_US pdf cad

    BSVP160-6B1A-Rebate-Window_Method-A-Part-1-of-3_US pdf cad

    BSVP160-6B1B-Rebate-Window_Method-A-Part-2-of-3_US pdf cad

    BSVP160-6B1C-Rebate-Window_Method-A-Part-3-of-3_US pdf cad

    BSVP160-6B2A-Rebate-Window_Method-B-Part-1-of-3_US pdf cad

    BSVP160-6B2B-Rebate-Window_Method-B-Part-2-of-3_US pdf cad

    BSVP160-6B2C-Rebate-Window_Method-B-Part-3-of-3_US pdf cad

    BSVP160-6C1A-Flanged-Window_Method-A-Part-1-of-3_US pdf cad

    BSVP160-6C1B-Flanged-Window_Method-A-Part-2-of-3_US pdf cad

    BSVP160-6C1C-Flanged-Window_Method-A-Part-3-of-3_US pdf cad

    BSVP160-6C2A-Flanged-Window_Method-B-Part-1-of-3_US pdf cad

    BSVP160-6C2B-Flanged-Window_Method-B-Part-2-of-3_US pdf cad

    BSVP160-6C2C-Flanged-Window_Method-B-Part-3-of-3_US pdf cad

    BSVP160-7A1-Reverse-Lap-Blueskin-VP160-onto-Blueskin-VP160_US pdf cad

    BSVP160-7B1-Reverse-Lap-Blueskin-Butyl-Flash-onto-Blueskin-VP160_US pdf cad

    BSVP160-7C1-Reverse-Lap-SBS-Flashing-onto-Blueskin-VP160_US pdf cad

    BSVP160-7D1-Reverse-Lap-Special-Conditions_US pdf cad

    BSVP160-8A1-Construction-Joints_Half-Inch-Gap-Max_US pdf cad

    BSVP160-8B1-Construction-Joints_Three-Quarter-Inch-Gap-Max_Convex-Loop_US pdf cad

    BSVP160-8B2-Construction-Joints_Three-Quarter-Inch-Gap-Max_Concave-Loop_US pdf cad

    BSVP160-8C1-Construction-Joints-Two-Inch-Gap-Max_Convex-Loop_US pdf cad

    BSVP160-8C2-Construction-Joints-Two-Inch-Gap-Max_Concave-Loop_US pdf cad

    BSVP160-9A1-Parapet_Air-Barrier-on-Front-and-Back-of-Parapet-Wall_US pdf cad

    BSVP160-9B1-Parapet_Roofing-Assembly-Wrapping-Over-Top-of-Parapet_US pdf cad

    BSVP-TID3A Blueskin VP160 transition with Pumadeq System pdf cad

  • LEED Declarations

    BlueskinVP LEED Declarations Click to download

    Blueskin Weather Barrier LEED Declarations Click to download

  • Health Product Declarations

    Blueskin® VP160 Health Product Declaration Click to download

  • Videos

Complete the form below and a representative will contact you shortly!