Air-Bloc® 16MR
Air-Bloc® 16MR
Fluid-Applied Air and Vapor Barrier
Henry Air-Bloc 16MR is a fluid-applied, vapor-impermeable air and water barrier when applied to above-grade wall assemblies. It is single-component, water-based, and cures to a tough monolithic rubber-like membrane, which resists air leakage and water penetration.
Sizes Available:
5 gal
55 gal
Product Details
- Product #HE016
Air-Bloc 16MR is a liquid-applied, elastomeric membrane designed to provide a vapor-impermeable air and water barrier when applied to above-grade wall assemblies. It is single-component, water-based, and cures to a tough monolithic rubber-like membrane, which resists air leakage and water penetration. Air-Bloc 16MR includes an antimicrobial technology to create an integral mold-resistant membrane, and offers a broad application temperature range with a proprietary fire resistance technology to achieve compliance with stringent NFPA 285 requirements.
- Seamless, vapor-impermeable elastomeric membrane for above-grade walls
- Integral mold-resistant formulation
-
NFPA 285 COMPLIANT
Proprietary fire-resistant technology provides superior fire performance for compliance with NFPA 285
-
VERSATILE APPLICATION
Excellent adhesion to most construction surfaces such as exterior gypsum boards, CMU, concrete, stone, wood and metal
-
COLD WEATHER APPLICATION
Low temperature application 20°F (-6°C) and rising with no additives required
Technical & Installation
-
Air-Bloc 16MR Spec Sheet
Download
-
Air-Bloc 16MR DWG Zip Files
Download
-
AB16MR-1A Wall Foundation Slab Below Grade
Download
-
AB16MR-1B Wall Foundation Slab on Grade
Download
-
AB16MR-1C Wall Foundation Transition No Brick Ledge
Download
-
AB16MR-2A Pipe Penetration 0.5 Inch Wide Gap Max
Download
-
AB16MR-2B Pipe Penetration 0.75 Inch Wide Gap Max
Download
-
AB16MR-3A-1 Inside and Outside Corners
Download
-
AB16MR-3A-2 Inside and Outside Corners
Download
-
AB16MR-3B Inside and Outside Corners
Download
-
AB16MR-3C Typical Soffit
Download
-
AB16MR-4A Substrate Transition
Download
-
AB16MR-4B Substrate Transition
Download
-
AB16MR-4C Substrate Transition
Download
-
AB16MR-5A Thru-Wall Flashing
Download
-
AB16MR-6A-A Flanged Window Section Method A
Download
-
AB16MR-6A-C Flanged Window Sequence Installation Method A
Download
-
AB16MR-6A1-A Flanged Window Section Method A1
Download
-
AB16MR-6A1-C Flanged Window Sequence Installation Method A1
Download
-
AB16MR-6B-A Non-Flanged Window Section Method B
Download
-
AB16MR-6B-C Non-Flanged Window Sequence Installation Method B
Download
-
AB16MR-6B1-A Non-Flanged Window Section Method B1
Download
-
AB16MR-6B1-C Non-Flanged Window Sequence Installation Method B1
Download
-
AB16MR-6C Door Frame Section
Download
-
AB16MR-7A1 Reverse Lap
Download
-
AB16MR-8A Construction Joints 0.5 Inch Gap Max
Download
-
AB16MR-8B1 Construction Joints 1 Inch Gap Max
Download
-
AB16MR-8C1 Construction Joints 2 Inch Gap Max
Download
-
AB16MR-8DA Deflection Joint
Download
-
AB16MR-8E Cracks 0.5 Inch Gap Max
Download
-
AB16MR-9A Roofing Wrapping Parapet
Download
-
AB16MR-9B Air Barrier Transition at Parapet
Download
-
AB16MR-TID3A Air-Bloc 16MR transition with Pumadeq System
Download
-
Henry Air Barrier Assemblies Meet ASTM E2357
Download
-
Henry Air Barrier and Waterproofing Membranes Earn Living Building Challenge Declare "Red List Free" Status
Download
-
NFPA 285 Assemblies
Download
-
Fastener penetrations through air barrier membranes
Download
-
Conversion Charts
Download
-
Coatings and Sealants
Download
-
Henry Living Building Challenge Red List
Download