WeatherSmart D

Exceeds drainage efficiency standards

WeatherSmart® D

WeatherSmart® D is a drainable weather-resistive barrier that performs at the highest drainage efficiency level, making it suitable for use in any climate. The high performance fabric is designed to withstand the rigors of the elements and jobsite. WeatherSmart D is effective for use in any climate and behind all exterior claddings, including fiber cement, vinyl and wood siding. It's an integral component of the wall assembly behind brick, stone and stucco.

When used as part of the Henry® 1-2-3 Moisture Control System™, WeatherSmart D is backed by an industry-leading 15-year warranty. Repairs are covered for both materials and labor with a single point of contact.

Features

  • Textured surfaces moves water down the wall
  • Achieves more than 95% drainage efficiency
  • Code compliant for use behind masonry
  • Part of approved NFPA 285 assemblies
  • Use interchangeably with WeatherSmart Drainable

Packaging

  • Roll Length: 125'
  • Roll Widths: 5', 9', 10'

Related products to qualify for the 15 year warranty

Literature

  • Data Sheets

    WeatherSmart® D Drainable Data Sheet Click to download  

    WeatherSmart® Drainable Safety Data Sheet Click to download  

    WeatherSmart® D Evaluation Report Click to download  

    NFPA 285 report Click to download  

    Code Compliance Research Report - 0442 Click to download  

  • Installation Guides

    Installation Guide Click to download

    Installation Guide – Before Window Installation Click to download

    Installation Guide – After Window Installation Click to download

  • Specifications

    WeatherSmart Drainable Specification Guide Click to download  

  • Architectural Details

    MAWRB-1A Wall Foundation Slab Below Grade pdf cad

    MAWRB-1B Wall Foundation Slab on Grade US pdf cad

    MAWRB-1C Wall Foundation Transition No Brick Ledge pdf cad

    MAWRB-2A Pipe Penetration 0.75 Inch Wide Gap Max pdf cad

    MAWRB-3A1 Outside Corners pdf cad

    MAWRB-3A2 Inside Corners pdf cad

    MAWRB-4A Substrate Transition pdf cad

    MAWRB-4B Substrate Transition pdf cad

    MAWRB-5A Thru-Wall Flashing pdf cad

    MAWRB-6A-L1 Flanged Window Section Method A - Low wind and water exposure pdf cad

    MAWRB-6A-L2 Flanged Window Sequence Installation Method A - Low wind and water exposure pdf cad

    MAWRB-6B-L1 Flanged Window Section Method B - Low wind and water exposure pdf cad

    MAWRB-6B-L2 Flanged Window Sequence Installation Method B - Low wind and water exposure pdf cad

    MAWRB-6C Hollow Metal Door pdf cad

    MAWRB-9A Air Barrier Transition at sloped roof pdf cad

    MAWRB-9B Roofing Wrapping Parapet pdf cad

    MAWRB-9C Air Barrier Transition at Parapet pdf cad

    MAWRB-1A Wall Foundation Slab Below Grade pdf cad

    MAWRB-1B Wall Foundation Slab on Grade pdf cad

    MAWRB-6A-F2 Flanged Window Sequence Installation Method A - Fortiflex Buytl pdf cad

    MAWRB-6A-F1 Flanged Window Section Method A - Fortiflex Butyl pdf cad

    MAWRB-6A1-F1 Flanged Window Section Method A1 - Fortiflex Butyl pdf cad

    MAWRB-6A1-F2 Flanged Window Sequence Installation Method A1 - Fortiflex Butyl pdf cad

  • Warranties

    15 Year Warranty Click to download

    Standard Warranty Click to download

  • Videos

Complete the form below to request a FREE sample!